|type=[[WARNING]] | |type=[[WARNING]] | ||
− | |message_desc=SGS Sample Target Distance <=0 = ignoring. | + | |message_desc=SGS Sample Target Distance <=0 = ignoring. The value set by the .tcf command "<tt><font color="blue">SGS Sample Target Distance </font><font color="red">==</font></tt>" is less than or equal to zero. Therefore, the value is ignored and the SGS sampling frequency is set by the .tgc command(s) "<tt><font color="blue">Read Grid Zpt</font><font color="red"> ==</font></tt>", or set to the default value of 11 per face (if no <tt><font color="blue">Read Grid Zpt</font></tt> specified). |
− | |suggestions= | + | |suggestions=Ensure "<tt><font color="blue">SGS Sample Target Distance </font><font color="red">==</font></tt>" is set to a value greater than 0. <br> |
+ | Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information on SGS sampling frequency. | ||
− | |||
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | |uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 15:20, 12 November 2024
TUFLOW Message
WARNING 3550 - SGS Sample Target Distance <=0 = ignoring.
Alternate Message
NA
Message Type
WARNING
Description
SGS Sample Target Distance <=0 = ignoring. The value set by the .tcf command "SGS Sample Target Distance ==" is less than or equal to zero. Therefore, the value is ignored and the SGS sampling frequency is set by the .tgc command(s) "Read Grid Zpt ==", or set to the default value of 11 per face (if no Read Grid Zpt specified).
Suggestions
Ensure "SGS Sample Target Distance ==" is set to a value greater than 0.
Refer to the TUFLOW Manual for more information on SGS sampling frequency.
Up |
---|