Line 4:
 
|type=[[ERROR]]
|message_desc=Invalid SGS ZH Sample Ratio. This value is used to control the area used for SGS at ZH locations and it should be between 0 and 1. The area is set to <tt><''ratio''> X ''cell_area''</tt> to sample and generate Z values around a cell corner (the sampled elevations are not used in the hydraulic computations, only for map output).
|message_desc=Invalid SGS ZH SAMPLE RATIO. This value should be 0 ~ 1.
|suggestions=Ensure the .tgc command "<tt><font color="blue">SGS ZH Sample Ratio</font><font color="red"> ==</font></tt>" is set to a value between 0 and 1.
|suggestions=Please contact [mailto:support@tuflow.com support@tuflow.com].
 