TUFLOW Message 1100: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 4: Line 4:
|type=[[WARNING]]
|type=[[WARNING]]
|message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel. <br>
|message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel. <br>
The following diagrams provide a simplified elevation view of the two cases that trigger this warning: <br>
The following diagrams provide a simplified elevation view of the two cases that trigger this warning: <br> <br>
'''''Structure "a" crest/invert is below bed of primary upstream channel'''''<br>
'''''Structure "a" crest/invert is below bed of primary upstream channel'''''<br>
[[File:Invert below US channel.png]] <br><br>
[[File:Invert below US channel.png]] <br><br>
'''''Structure "a" crest/invert is below bed of primary downstream channel'''''<br>
'''''Structure "a" crest/invert is below bed of primary downstream channel'''''<br> <br>
[[File:Invert below DS channel.png]] <br>
[[File:Invert below DS channel.png]] <br>
<br>
<br>
|suggestions= For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.
|suggestions= For Build 2013-12-AB onwards, if this warning is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results. <br>
From Build 2023-03-AD onwards, this warning is eliminated when the connecting node is a manhole. Manholes often feature elevation drops between culverts making this warning unnecessary.


|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]

Latest revision as of 15:30, 30 September 2024

TUFLOW Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary upstream channel "b".

Alternate Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b".

Message Type
WARNING

Description
The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel.
The following diagrams provide a simplified elevation view of the two cases that trigger this warning:

Structure "a" crest/invert is below bed of primary upstream channel


Structure "a" crest/invert is below bed of primary downstream channel



Suggestions
For Build 2013-12-AB onwards, if this warning is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.
From Build 2023-03-AD onwards, this warning is eliminated when the connecting node is a manhole. Manholes often feature elevation drops between culverts making this warning unnecessary.


Up
1xxx Messages