Difference between revisions of "TUFLOW Message 2320"
Jump to navigation
Jump to search
Line 5: | Line 5: | ||
ERROR 2320 - TUFLOW 2016-03 GPU Solver does not support 1D links.<br> | ERROR 2320 - TUFLOW 2016-03 GPU Solver does not support 1D links.<br> | ||
ERROR 2320 - GLO commands not yet supported in HPC or GPU solver.<br> | ERROR 2320 - GLO commands not yet supported in HPC or GPU solver.<br> | ||
+ | ERROR 2320 - "Bed Resistance Values == CHEZY" not supported in HPC solver.<br> | ||
+ | ERROR 2320 - "Bed Resistance Values == MANNING M" not supported in HPC solver.<br> | ||
WARNING 2320 - HPC or GPU Solver ignoring Read GIS Objects/Receptors commands.<br> | WARNING 2320 - HPC or GPU Solver ignoring Read GIS Objects/Receptors commands.<br> | ||
|type=[[WARNING]]<br> | |type=[[WARNING]]<br> |
Latest revision as of 16:03, 26 May 2025
TUFLOW Message
ERROR 2320 - FC commands not yet supported in HPC or GPU solver.
Alternate Message
ERROR 2320 - Read TGF command not yet supported in HPC or GPU solver.
ERROR 2320 - Read TGA command not yet supported in HPC or GPU solver.
ERROR 2320 - TUFLOW 2016-03 GPU Solver does not support 1D links.
ERROR 2320 - GLO commands not yet supported in HPC or GPU solver.
ERROR 2320 - "Bed Resistance Values == CHEZY" not supported in HPC solver.
ERROR 2320 - "Bed Resistance Values == MANNING M" not supported in HPC solver.
WARNING 2320 - HPC or GPU Solver ignoring Read GIS Objects/Receptors commands.
Description
Some TUFLOW Classic functionalities are not supported by the TUFLOW HPC solver.
Suggestions
- If using a 2d_fc layer, change to a 2d_lfcsh layer which is supported by TUFLOW HPC.
- The 2016-03 TUFLOW GPU solver is a legacy feature, TUFLOW HPC (on GPU hardware) should be used instead.
- GLO commands are supported in TUFLOW HPC from the 2023-03-AD build and onwards.
- Read GIS Objects/Receptors commands are supported in TUFLOW HPC from the 2023-03-AA build and onwards.
Up |
---|
![]() |