Line 3:
|alt_msg=NA
|type=[[ERROR]]
|message_desc=The Material ID specified in the cross-section is not defined in the materials dataset (as defined by the <font color="blue"><tt>Read Materials File </tt></font><font color="red"><tt>== "</tt></font> in the .tcf). When using the "M" flag on 1D cross-sections, TUFLOW is expecting an integer material ID. The roughness value is obtained from the material dataset.<br>
This is in contrast to the "N" flag, if this flag is used the Manning's value is defined on the cross-section.
|suggestions=Check that the material ID specified exists in the Materials dataset. If the outputted material ID in the error message is 0, check that a material ID and not a Manning's value has been specified on the cross-section.
 
|discussion_page=* [[Talk:TUFLOW Message 1069|Discuss Message 1069]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1068|Message 1068]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1070|Message 1070]]
}}