TUFLOW Message 1041: Difference between revisions
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1041 - Culvert branch splits downstream of channel ",a," at Node ",a,". Could not interpolate invert. |alt_msg=ERROR 1041 - Culvert branch...' |
No edit summary |
||
| (4 intermediate revisions by 2 users not shown) | |||
Line 3:
|alt_msg=ERROR 1041 - Culvert branch splits upstream of channel ",a," at Node ",a,". Could not interpolate invert.
|type=[[ERROR]]
|message_desc=Multiple upstream or downstream channel, unable to interpolate inverts.
|suggestions=A useful tip at a junction of 1D channels is to use a connector (Channel_Type of “X”) for connecting a side tributary or pipe into the main flowpath. TUFLOW will then be able to interpolate inverts.<br>
Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
}}
| |||