TUFLOW Message 1042: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1042 - Could not find a culvert invert downstream of culvert ",a,". Downstream invert not interpolated. |alt_msg=ERROR 1042 - Could not fi...'
 
No edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 3: Line 3:
|alt_msg=ERROR 1042 - Could not find a culvert invert upstream of culvert ",a,". Upstream invert not interpolated.
|alt_msg=ERROR 1042 - Could not find a culvert invert upstream of culvert ",a,". Upstream invert not interpolated.
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=No upstream / downstream invert specified, TUFLOW is unable to interpolate an invert.
|message_desc=????
|suggestions=Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.
|suggestions=????

|discussion_page=* [[Talk:TUFLOW Message 1042|Discuss Message 1042]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1041|Message 1041]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1043|Message 1043]]
}}
}}

Latest revision as of 14:26, 22 December 2022

TUFLOW Message
ERROR 1042 - Could not find a culvert invert downstream of culvert ",a,". Downstream invert not interpolated.

Alternate Message
ERROR 1042 - Could not find a culvert invert upstream of culvert ",a,". Upstream invert not interpolated.

Message Type
ERROR

Description
No upstream / downstream invert specified, TUFLOW is unable to interpolate an invert.

Suggestions
Specify inverts upstream and downstream of the culvert, either via the US_invert / DS_invert in the 1D channel object or via snapped 1D node objects.


Up