Difference between revisions of "TUFLOW Message 1057"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1057 - Invalid flag(s) specified. Flags: ",a, |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |discussion_page=* [[Talk:T...')
 
 
(4 intermediate revisions by 2 users not shown)
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=The flag specified for a XZ, CS or HW table is invalid.
|suggestions=????
+
|suggestions= Ensure the specified flag in the 1d_tab layer is permitted. <br>
|discussion_page=* [[Talk:TUFLOW Message 1057|Discuss Message 1057]]
+
<br>
|link3=''
+
Permitted flags for XZ Tables are: <br>
|link4=''
+
* R, M or N (relative resistance)
|prelink=[[TUFLOW_Message_1056|Message 1056]]
+
* E or T (effective or total area)
 +
* P (Position value of left bank, right bank, and mainstream)
 +
* A (addition value to raise or lower the Z value) <br>
 +
<br>
 +
Permitted flags for CS or HW Tables are: <br>
 +
* A (flow area)
 +
* P (wetted perimeter)
 +
* F or N (vertical change in resistance)
 +
* E (effective flow width)
 +
 
 +
Refer to Table 4.17 of the 2010 Manual for further information. <br>
 +
 
 +
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1058|Message 1058]]
 
 
}}
 
}}

Latest revision as of 14:30, 22 December 2022

TUFLOW Message
ERROR 1057 - Invalid flag(s) specified. Flags: ",a,

Alternate Message
NA

Message Type
ERROR

Description
The flag specified for a XZ, CS or HW table is invalid.

Suggestions
Ensure the specified flag in the 1d_tab layer is permitted.

Permitted flags for XZ Tables are:

  • R, M or N (relative resistance)
  • E or T (effective or total area)
  • P (Position value of left bank, right bank, and mainstream)
  • A (addition value to raise or lower the Z value)


Permitted flags for CS or HW Tables are:

  • A (flow area)
  • P (wetted perimeter)
  • F or N (vertical change in resistance)
  • E (effective flow width)

Refer to Table 4.17 of the 2010 Manual for further information.