Difference between revisions of "TUFLOW Message 1068"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1068 - First column values in cross-section data not in ascending order. Incorrect values are: |alt_msg=NA |type=ERROR |message_desc=?...') |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=The data in the first column of a cross-section is not unique or in ascending order. For a XZ (offset - elevation), the X data (offset) should be unique and in ascending order. The same applies to all cross-section types, e.g. for a HW (height - width) section, the height values should be increasing. |
− | |suggestions= | + | |suggestions=Check data, remove duplicate values and sort by first column. |
− | + | ||
− | + | ||
− | |||
− | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 14:38, 22 December 2022
TUFLOW Message
ERROR 1068 - First column values in cross-section data not in ascending order. Incorrect values are:
Alternate Message
NA
Message Type
ERROR
Description
The data in the first column of a cross-section is not unique or in ascending order. For a XZ (offset - elevation), the X data (offset) should be unique and in ascending order. The same applies to all cross-section types, e.g. for a HW (height - width) section, the height values should be increasing.
Suggestions
Check data, remove duplicate values and sort by first column.
Up |
---|
1xxx Messages |