TUFLOW Message 2444: Difference between revisions

Content deleted Content added
Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2444 - ???? |alt_msg=WARNING 2444 - ???? |type=ERROR WARNING |message_desc=An ERROR (2012-05 TUFLOW release) or a WARNING (if De..."
 
No edit summary
 
(7 intermediate revisions by 3 users not shown)
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 2444 - ????ZU of "a" outside Zpt Range Check.
|alt_msg=WARNING 2444 - ????ZU of "a" outside Zpt Range Check.
|type=[[ERROR]] <br>[[WARNING]]
|message_desc=An ERROR (2012-05 TUFLOW release) or a WARNING (if Defaults==pre-2012) is issued if a final zpt elevation less than zmin or greater than zmax as defined by the command '''Zpt Range Check''' has been found.
|suggestions=TheImport defaultsin forthe zminmessages.MIF/.SHP and zmax are -9998file and 99998. Checkcheck for erroneous zpt elevations outside of thisthe range.ranges Alternatively, thefor zmin and zmax. elevationsIf these have cannot bebeen manually defined using the tcf command '''Zpt Range Check''', the default values are -9998 for zmin and 99998 for zmax.
 
|discussion_page=* [[Talk:TUFLOW Message 2444|Discuss Message 2444]]
 
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2443|Message 2443]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|nextlink=[[TUFLOW_Message_2445|Message 2445]]
}}