TUFLOW Message 1118: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1118 - Could not find pit inlet type ",a," in the pit inlet database. |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |dis...'
 
No edit summary
 
(4 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{TUFLOW_Message
{{TUFLOW_Message
|tuflow_message=ERROR 1118 - Could not find pit inlet type ",a," in the pit inlet database.
|tuflow_message=ERROR 1118 - Could not find pit inlet type ",a," in the pit inlet database.
|alt_msg=ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database.
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples, refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>.
|message_desc=????
|suggestions=Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified.
|suggestions=????

|discussion_page=* [[Talk:TUFLOW Message 1118|Discuss Message 1118]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1117|Message 1117]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1119|Message 1119]]
}}
}}

Latest revision as of 09:52, 23 September 2024

TUFLOW Message
ERROR 1118 - Could not find pit inlet type ",a," in the pit inlet database.

Alternate Message
ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database.

Message Type
ERROR

Description
For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples, refer to the TUFLOW Manual.

Suggestions
Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified.


Up
1xxx Messages