Line 4:
|type=[[ERROR]]
|message_desc=If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).<br>
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.<br>
This error can also occur if you have a pit or node object, which is not correctly snapped to a channel.
|suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.<br>
|discussion_page=* [[Talk:TUFLOW Message 1353|Discuss Message 1353]]
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.
|link3=''
 
|link4=''
|prelink=[[TUFLOW_Message_1352|Message 1352]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]