Difference between revisions of "TUFLOW Message 1203"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1203 - Invalid Conn_2D attribute at node. Cannot exceed 3 characters. |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |di...') |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=An illegal Conn_2D attribute has been inputted on a 1d pit or node object. The Conn_2D attribute is used to automatically link to the 2D. Valid options are available:<br> |
− | + | *SX<br> | |
− | + | *SXL<br> | |
− | | | + | *SXZ<br> |
− | + | *SXG<br> | |
− | + | *SXS<br> | |
+ | For a detalied description of these options, refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>. | ||
+ | |suggestions=Specify a valid attribute as per the list above. | ||
+ | |||
+ | |||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 09:44, 23 September 2024
TUFLOW Message
ERROR 1203 - Invalid Conn_2D attribute at node. Cannot exceed 3 characters.
Alternate Message
NA
Message Type
ERROR
Description
An illegal Conn_2D attribute has been inputted on a 1d pit or node object. The Conn_2D attribute is used to automatically link to the 2D. Valid options are available:
- SX
- SXL
- SXZ
- SXG
- SXS
For a detalied description of these options, refer to the TUFLOW Manual.
Suggestions
Specify a valid attribute as per the list above.
Up |
---|
1xxx Messages |