TUFLOW Message 1261: Difference between revisions
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1261 - Invalid Manning''s n value of ",a," assigned to channel |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |discussio...' |
No edit summary |
||
| (3 intermediate revisions by 2 users not shown) | |||
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 1261 - Invalid Manning
|alt_msg=NA
|type=[[ERROR]]
|message_desc=Invalid Manning's n value assigned to channel, this will occur for a 0 or negative Manning's n value.
|suggestions=Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process).
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
}}
| |||