|tuflow_message=ERROR 1527  
+
|tuflow_message=ERROR 1527 - Could not find Operating Control Definition for Channel 'a'.
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=
+
|message_desc= The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found.
|suggestions=
+
|suggestions= Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and <font color="blue"><tt>Define Control </tt></font> <font color="red"><tt>==</tt></font> … <font color="blue"><tt>End Define </tt></font> logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic.
|discussion_page=* [[Talk:TUFLOW Message 1527|Discuss Message 1527]]
+
 
|link3=''
 
|link4=''
 
|prelink=[[TUFLOW_Message_1402|Message 1402]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1991|Message 1991]]
 
 
}}
 
}}

Latest revision as of 10:48, 23 December 2022

TUFLOW Message
ERROR 1527 - Could not find Operating Control Definition for Channel 'a'.

Alternate Message
NA

Message Type
ERROR

Description
The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found.

Suggestions
Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and Define Control ==End Define logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic.


Up