TUFLOW Message 1527: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Steph.dufour (talk | contribs) No edit summary |
No edit summary |
||
| (12 intermediate revisions by 3 users not shown) | |||
| Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=ERROR 1527 - Could not find Operating Control Definition for Channel |
|tuflow_message=ERROR 1527 - Could not find Operating Control Definition for Channel 'a'. |
||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc= The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found. |
|||
|message_desc= |
|||
|suggestions= Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and <font color="blue"><tt>Define Control </tt></font> <font color="red"><tt>==</tt></font> … <font color="blue"><tt>End Define </tt></font> logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic. |
|||
|suggestions= |
|||
|discussion_page=* [[Talk:TUFLOW Message 1527|Discuss Message 1527]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_1402|Message 1402]] |
|||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_1991|Message 1991]] |
|||
}} |
}} |
||
Latest revision as of 10:48, 23 December 2022
TUFLOW Message
ERROR 1527 - Could not find Operating Control Definition for Channel 'a'.
Alternate Message
NA
Message Type
ERROR
Description
The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found.
Suggestions
Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and Define Control == … End Define logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic.
| Up |
|---|