|message_desc=The value in column 1 of the 1d_ta file does not increase as it progresses, as shown in the example below. This is usually the 'X' value for an XZ type table; or 'H' value for a HW type table.
|message_desc=????
<br>
|suggestions=????
[[File:Non-incremental_HW_Table.png|320px]]
|discussion_page=* [[Talk:TUFLOW Message 1343|Discuss Message 1343]]
<br>
|link3=''
|suggestions=If there is a stepped increment in the 1d cross-section that you are trying to represent; it is possible to resolve this error by using a small increment of a millimetre between values in column 1 of the 1d_ta file.
|link4=''

|prelink=[[TUFLOW_Message_1342|Message 1342]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1344|Message 1344]]
}}
}}

Latest revision as of 10:34, 23 December 2022

TUFLOW Message
ERROR 1343 - In ',A4,1X,a,' table above, Column 1 values not increasing. Values: ',a,' then

Alternate Message
NA

Message Type
ERROR

Description
The value in column 1 of the 1d_ta file does not increase as it progresses, as shown in the example below. This is usually the 'X' value for an XZ type table; or 'H' value for a HW type table.

Suggestions
If there is a stepped increment in the 1d cross-section that you are trying to represent; it is possible to resolve this error by using a small increment of a millimetre between values in column 1 of the 1d_ta file.