{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message=ERROR 1353 - No | + | |tuflow_message=ERROR 1353 - No NA data for Node <Node ID> |
− | |alt_msg= | + | |alt_msg=ERROR 1353 - No CS data for Chan <Chan ID> |
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).<br> |
− | + | If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.<br> | |
− | + | This error can also occur if you have a pit or node object, which is not correctly snapped to a channel. | |
− | | | + | |suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.<br> |
− | + | If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel. | |
− | + | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 10:37, 23 December 2022
TUFLOW Message
ERROR 1353 - No NA data for Node <Node ID>
Alternate Message
ERROR 1353 - No CS data for Chan <Chan ID>
Message Type
ERROR
Description
If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.
This error can also occur if you have a pit or node object, which is not correctly snapped to a channel.
Suggestions
Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.