TUFLOW Message 2060: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
 
(10 intermediate revisions by 4 users not shown)
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 20612060 - CouldUnrecognisable not find.tbc acommand CNor connectionproblem snappedreading toBC thedata endin offixed HXfield lineformat.<br>
Incorrect Line = "xxxxxx"
|alt_msg=NA
|type=[[ERROR]]
|message_desc=.tbc command is invalid or BC input file (e.g. bd_dbase.csv, HT/QT table, and etc) isn't in the correct data format.
|message_desc=Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain.
|suggestions=Check which line in the input file is causing the issue from the error message, and ensure that .tbc command has no misspelling, or the input data is in the correct format.
|suggestions=????
 
|discussion_page=* [[Talk:TUFLOW Message 2061|Discuss Message 2061]]
 
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2060|Message 2060]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2062|Message 2062]]
}}