Line 4: Line 4:
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0).
|message_desc=Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0).
|suggestions=If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used.
|suggestions=????

|discussion_page=* [[Talk:TUFLOW Message 2063|Discuss Message 2063]]

|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2062|Message 2062]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2064|Message 2064]]
}}
}}

Latest revision as of 11:54, 23 December 2022

TUFLOW Message
ERROR 2063 - Single CN connection to 1D Node must have a weighting factor (f) of 1.0.

Alternate Message
NA

Message Type
ERROR

Description
Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0).

Suggestions
If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used.