Difference between revisions of "TUFLOW Message 2126"

From Tuflow
Jump to navigation Jump to search
 
(7 intermediate revisions by 5 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 2126 - Material resistance values can only be specified for Manning''s n at present.
+
|tuflow_message=ERROR 2126 - Material resistance values can only be specified for Manning's n at present.
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=Material resistance values can only be specified for Manning's n.
+
|message_desc=When using 2d_mat materials layers and a material file to define bed resistance for the 2D domain, the .tcf command <font color="blue"><tt>Bed Resistance Values</font><font color=red> == </tt></font> must be set to <tt>MANNING N</tt>. <br>
|suggestions=????
+
Refer to the TCF Appendix in the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more details.
|discussion_page=* [[Talk:TUFLOW Message 2126|Discuss Message 2126]]
+
|suggestions=In the .tcf, set <font color="blue"><tt>Bed Resistance Values</tt></font><font color="red"><tt> == </tt></font><tt>MANNING N</tt>.<br>
|link3=''
+
If bed resistance values are specified using the .tgc commands <font color="blue"><tt>Set CnM</tt></font><font color="red"><tt> == </tt></font>, <font color="blue"><tt>Read GIS CnM</tt></font><font color="red"><tt> == </tt></font> or <font color="blue"><tt>Read Grid CnM</tt></font><font color="red"><tt> == </tt></font> ensure the <font color="blue"><tt>Read Materials File</tt></font><font color="red"><tt> == </tt></font> command is commented out or removed from the .tcf.
|link4=''
+
 
|prelink=[[TUFLOW_Message_2125|Message 2125]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2127|Message 2127]]
 
 
}}
 
}}

Latest revision as of 10:49, 29 May 2025

TUFLOW Message
ERROR 2126 - Material resistance values can only be specified for Manning's n at present.

Alternate Message
NA

Message Type
ERROR

Description
When using 2d_mat materials layers and a material file to define bed resistance for the 2D domain, the .tcf command Bed Resistance Values == must be set to MANNING N.
Refer to the TCF Appendix in the TUFLOW Manual for more details.

Suggestions
In the .tcf, set Bed Resistance Values == MANNING N.
If bed resistance values are specified using the .tgc commands Set CnM == , Read GIS CnM == or Read Grid CnM == ensure the Read Materials File == command is commented out or removed from the .tcf.


Up
Go-up.png 2xxx Messages