TUFLOW Message
ERROR 1057 - Invalid flag(s) specified. Flags: ",a,
Alternate Message
NA
Message Type
ERROR
Description
The flag specified for a XZ, CS or HW table is invalid.
Suggestions
Ensure the specified flag in the 1d_tab layer is permitted.
Permitted flags for XZ Tables are:
- R, M or N (relative resistance)
- E or T (effective or total area)
- P (Position value of left bank, right bank, and mainstream)
- A (addition value to raise or lower the Z value)
Permitted flags for CS or HW Tables are:
- A (flow area)
- P (wetted perimeter)
- F or N (vertical change in resistance)
- E (effective flow width)
Refer to Table 4.17 of the 2010 Manual for further information.