− | |message_desc= | + | |message_desc=Invalid Manning's n value assigned to channel, this will occur for a 0 or negative Manning's n value. |
− | |suggestions= | + | |suggestions=Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process). |
|discussion_page=* [[Talk:TUFLOW Message 1261|Discuss Message 1261]] | |discussion_page=* [[Talk:TUFLOW Message 1261|Discuss Message 1261]] | ||
|link3='' | |link3='' |
Revision as of 09:28, 2 February 2011
TUFLOW Message
ERROR 1261 - Invalid Manning's n value of ",a," assigned to channel
Alternate Message
NA
Message Type
ERROR
Description
Invalid Manning's n value assigned to channel, this will occur for a 0 or negative Manning's n value.
Suggestions
Assign a valid Manning's n value for channel. If material values are defined in the XZ cross-section ("M" flag), the n_or_n_F attribute in the 1d_nwk is a multiplication factor and should be set to 1 (this may be adjusted as part of the calibration process).