Difference between revisions of "TUFLOW Message 1154"
Jump to navigation
Jump to search
Line 5: | Line 5: | ||
|message_desc=A downstream end cross-section is specified, but no upstream end cross-section is specified. This may result in a 0 gradient channel. | |message_desc=A downstream end cross-section is specified, but no upstream end cross-section is specified. This may result in a 0 gradient channel. | ||
|suggestions=Specify a upstream end cross-section, or ensure that inverts are appropriate if using only a downstream end cross-section. | |suggestions=Specify a upstream end cross-section, or ensure that inverts are appropriate if using only a downstream end cross-section. | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_1153|Message 1153]] | |prelink=[[TUFLOW_Message_1153|Message 1153]] | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_1156|Message 1156]] | |nextlink=[[TUFLOW_Message_1156|Message 1156]] | ||
}} | }} |
Revision as of 13:54, 5 July 2022
TUFLOW Message
CHECK 1154 - For channel ",a,", no upstream end cross-section specified (using downstream end cross-section).
Alternate Message
NA
Message Type
CHECK
Description
A downstream end cross-section is specified, but no upstream end cross-section is specified. This may result in a 0 gradient channel.
Suggestions
Specify a upstream end cross-section, or ensure that inverts are appropriate if using only a downstream end cross-section.
Up |
---|