Revision as of 15:55, 5 July 2022

TUFLOW Message
ERROR 2014 - No active cells within SA inflow polygon.

Alternate Message
NA

Message Type
ERROR

Description
No active 2D cells within Source over Area (SA) inflow polygon.

Suggestions
Source-Area polygon in outside of active model code. Check SA polygon is in the correct location, active model area (2D code) may need to be extended.


Up
2xxx Messages