Difference between revisions of "TUFLOW Message 2060"
Line 4: | Line 4: | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain. | |message_desc=Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain. | ||
− | |suggestions=Ensure that there is a CN object at each end of HX line connecting HX line to 1D node. | + | |suggestions=Ensure that there is a CN object at each end of HX line connecting HX line to 1D node. The messages.mif or messages_P.shp file should contain the location that this error is occurring. Zoom into the HX line and check that the connection line is snapped to the end vertices of the line. This line can have CN connections snapped to intermediate vertices, but <u>'''must '''</u> have a CN line snapped to each end. |
|discussion_page=* [[Talk:TUFLOW Message 2061|Discuss Message 2061]] | |discussion_page=* [[Talk:TUFLOW Message 2061|Discuss Message 2061]] | ||
|link3='' | |link3='' | ||
Line 10: | Line 10: | ||
|prelink=[[TUFLOW_Message_2060|Message 2060]] | |prelink=[[TUFLOW_Message_2060|Message 2060]] | ||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
− | |nextlink=[[TUFLOW_Message_2062|Message | + | |nextlink=[[TUFLOW_Message_2062|Message 2061]] |
}} | }} |
Revision as of 12:01, 9 July 2012
TUFLOW Message
ERROR 2061 - Could not find a CN connection snapped to the end of HX line.
Alternate Message
NA
Message Type
ERROR
Description
Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain.
Suggestions
Ensure that there is a CN object at each end of HX line connecting HX line to 1D node. The messages.mif or messages_P.shp file should contain the location that this error is occurring. Zoom into the HX line and check that the connection line is snapped to the end vertices of the line. This line can have CN connections snapped to intermediate vertices, but must have a CN line snapped to each end.
Up |
---|
2xxx Messages |