Line 5: | Line 5: | ||
|message_desc=Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object. | |message_desc=Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object. | ||
|suggestions=SC line should only be used with SH boundary object. For SX and HX connections use CN objects. | |suggestions=SC line should only be used with SH boundary object. For SX and HX connections use CN objects. | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_2061|Message 2061]] | |prelink=[[TUFLOW_Message_2061|Message 2061]] | ||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_2063|Message 2063]] | |nextlink=[[TUFLOW_Message_2063|Message 2063]] | ||
}} | }} |
Revision as of 13:08, 6 July 2022
TUFLOW Message
ERROR 2062 - SC connection cannot connect to a HX line.
Alternate Message
NA
Message Type
ERROR
Description
Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object.
Suggestions
SC line should only be used with SH boundary object. For SX and HX connections use CN objects.