Difference between revisions of "TUFLOW Message 2063"
Jump to navigation
Jump to search
Line 5: | Line 5: | ||
|message_desc=Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0). | |message_desc=Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0). | ||
|suggestions=If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used. | |suggestions=If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used. | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_2062|Message 2062]] | |prelink=[[TUFLOW_Message_2062|Message 2062]] | ||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_2064|Message 2064]] | |nextlink=[[TUFLOW_Message_2064|Message 2064]] | ||
}} | }} |
Revision as of 13:08, 6 July 2022
TUFLOW Message
ERROR 2063 - Single CN connection to 1D Node must have a weighting factor (f) of 1.0.
Alternate Message
NA
Message Type
ERROR
Description
Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0).
Suggestions
If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used.
Up |
---|