Difference between revisions of "TUFLOW Message 2124"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[WARNING]] | |type=[[WARNING]] | ||
− | |message_desc=No 2D connection specified for pit. Usually indicates that the SX has been omitted or typed incorectly in the 1d_nwk Topo_ID | + | |message_desc=No 2D connection specified for pit. Usually indicates that the SX has been omitted or typed incorectly in the 1d_nwk GIS attribute Conn_2D |
− | |suggestions=Review pit to see if connection to the 2D model is intended. | + | (previously Topo_ID). |
+ | |suggestions=Review pit to see if connection to the 2D model is intended, if so specify a valid connection type in the Conn_2D attribute. | ||
|discussion_page=* [[Talk:TUFLOW Message 2124|Discuss Message 2124]] | |discussion_page=* [[Talk:TUFLOW Message 2124|Discuss Message 2124]] | ||
|link3='' | |link3='' |
Revision as of 13:29, 15 February 2011
TUFLOW Message
WARNING 2124 - No 2D connection specified for pit or node.
Alternate Message
NA
Message Type
WARNING
Description
No 2D connection specified for pit. Usually indicates that the SX has been omitted or typed incorectly in the 1d_nwk GIS attribute Conn_2D
(previously Topo_ID).
Suggestions
Review pit to see if connection to the 2D model is intended, if so specify a valid connection type in the Conn_2D attribute.
Up |
---|
2xxx Messages |