TUFLOW Message 2050: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc="The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or e...'
 
No edit summary
Line 1: Line 1:
{{TUFLOW_Message
{{TUFLOW_Message
|tuflow_message=ERROR 2050 - Lowest ZC elevation at/along SX link is above 1D node bed.
|tuflow_message=????
|alt_msg=WARNING 2050 - Lowest ZC elevation at/along SX link is above 1D node bed.
|type=[[ERROR]] <br> [[WARNING]]
|message_desc="The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or element. The lowest ZC level at or along the 1D/2D interface plus the 2D cell's wet/dry depth must be below the bed of the connected 1D element for SX type 1D/2D connections. SX connections are usually used for embedding small 1D elements such as pipes, culverts and manholes/pits. Treatment of this message as an ERROR or a WARNING is controlled by the ""SX ZC Check"" command. The ZC level of the 2D cell can be automatically lowered using ""Z"" in the Flag attribute for the object - see table of 2d_bc attributes in the manual."
|message_desc="The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or element. The lowest ZC level at or along the 1D/2D interface plus the 2D cell's wet/dry depth must be below the bed of the connected 1D element for SX type 1D/2D connections. SX connections are usually used for embedding small 1D elements such as pipes, culverts and manholes/pits. Treatment of this message as an ERROR or a WARNING is controlled by the ""SX ZC Check"" command. The ZC level of the 2D cell can be automatically lowered using ""Z"" in the Flag attribute for the object - see table of 2d_bc attributes in the manual."
|suggestions=????
|suggestions=????
Line 7: Line 9:
|link4=''
|link4=''
|prelink=[[TUFLOW_Message_2049|Message 2049]]
|prelink=[[TUFLOW_Message_2049|Message 2049]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2051|Message 2051]]
|nextlink=[[TUFLOW_Message_2051|Message 2051]]
}}
}}

Revision as of 11:43, 1 October 2010

TUFLOW Message
ERROR 2050 - Lowest ZC elevation at/along SX link is above 1D node bed.

Alternate Message
WARNING 2050 - Lowest ZC elevation at/along SX link is above 1D node bed.

Message Type
ERROR
WARNING

Description
"The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or element. The lowest ZC level at or along the 1D/2D interface plus the 2D cell's wet/dry depth must be below the bed of the connected 1D element for SX type 1D/2D connections. SX connections are usually used for embedding small 1D elements such as pipes, culverts and manholes/pits. Treatment of this message as an ERROR or a WARNING is controlled by the ""SX ZC Check"" command. The ZC level of the 2D cell can be automatically lowered using ""Z"" in the Flag attribute for the object - see table of 2d_bc attributes in the manual."

Suggestions
????


Up
2xxx Messages