Difference between revisions of "TUFLOW Message 2011"

From Tuflow
Jump to navigation Jump to search
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=A .tgc materials command such as Set Mat == or Read GIS Mat == has been specified, but Read Materials File == in the .tcf file has not been specified.  A materials file must be specified if .tgc Mat commands are used.  <br>
+
|message_desc=A .tgc materials command such as Set Mat ==, Read GIS Mat == or Read RowCol Grid == has been specified, but Read Materials File == in the .tcf file has not been specified.  A materials file must be specified if .tgc Mat commands are used.  <br>
  
 
This ERROR was introduced in Build 2010-10-AC.  Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used.  The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br>
 
This ERROR was introduced in Build 2010-10-AC.  Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used.  The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br>

Revision as of 10:58, 12 April 2011

TUFLOW Message
ERROR 2011 - Using Mat command when no materials file has been specified.

Alternate Message
NA

Message Type
ERROR

Description
A .tgc materials command such as Set Mat ==, Read GIS Mat == or Read RowCol Grid == has been specified, but Read Materials File == in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used.

This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.

Suggestions
{{{suggestions}}}


Up
Go-up.png 2xxx Messages