== Test Case 1 - Discussion ==
The graphed results indicate convergence is observed for all cases with a cell resolution equal to or less than 100m. The grid figures presented to the right of the graphs suggest the 100m cell resolution case has approximately (4) four cells laterally across the valley
Simulation time can influence model resolution selection. This is not the case in this situation. All models have run in under 5 minutes using TUFLOW HPC's GPU hardware module.
| |||