Line 5: Line 5:
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells.
|message_desc=A 1D pit object can be connected to a maximum of 10 2D cells.
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.

|discussion_page=* [[Talk:TUFLOW Message 2215|Discuss Message 2215]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_2214|Message 2214]]
|prelink=[[TUFLOW_Message_2214|Message 2214]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]

Revision as of 14:25, 6 July 2022

TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.

Alternate Message
NA

Message Type
WARNING

Description
A 1D pit object can be connected to a maximum of 10 2D cells.

Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.


Up
2xxx Messages