| {{TUFLOW_Message | {{TUFLOW_Message | ||
| |tuflow_message=CHECK 1625 - Unconnected pit | |tuflow_message=CHECK 1625 - Unconnected pit. | ||
| |alt_msg=CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR. | |alt_msg=CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR. | ||
| |type=[[CHECK]] | |type=[[CHECK]] | ||
Revision as of 14:34, 2 January 2019
TUFLOW Message 
CHECK 1625 - Unconnected pit.
Alternate Message 
CHECK 1625 - Could not find any channel ends for Pit XXX. 1D virtual pipe connection assumed. To treat as an ERROR use PIT NO 1D CONNECTION == ERROR.
Message Type 
CHECK
Description 
Pit is not snapped or within the Pit Search Distance  ==, and will be modelled as an 1D virtual pipe.
Suggestions 
If the pit must be connected to a 1D channel, use the ECF command Pit No 1D Connection  == ERROR to force an error and check the pit connection. See also ERROR 1626.