|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
|message_desc=From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.

|discussion_page=* [[Talk:TUFLOW Message 1214|Discuss Message 1214]]
|link3=''
|link4=''
|prelink=[[TUFLOW_Message_1213|Message 1213]]
|prelink=[[TUFLOW_Message_1213|Message 1213]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]

Revision as of 14:02, 5 July 2022

TUFLOW Message
ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.

Alternate Message
WARNING 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.

Message Type
ERROR,WARNING

Description
From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).

Suggestions
If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.


Up
1xxx Messages