An ESTRY X1DH (the default) would be used for most Flood Modeller ESTRY links where TUFLOW is discharging into Flood Modeller. The discharge will be applied to the Flood Modeller 1D model as a lateral inflow. The Flood Modeller 1D node on the receiving end of an X1DH connection must be a channel unit (eg, River, Interpolate, Replicate or Conduit) and must not be the end node of a reach (ie, distance to next cross section of zero). This is commonly used when representing a pipe network within ESTRY which discharges to an open channel represented in Flood Modeller as per Figure 1.
[[File:X1DH Link.png|700px
'''NOTE: Remember that the Flood Modeller node ID is Case Sensitive.'''
| |||