Difference between revisions of "TUFLOW Message 2980"
Jump to navigation
Jump to search
Line 11: | Line 11: | ||
|link3='' | |link3='' | ||
|link4='' | |link4='' | ||
− | |prelink=[[ | + | |prelink=[[TUFLOW_Message_2845|Message 2845]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_2991|Message 2991]] | |nextlink=[[TUFLOW_Message_2991|Message 2991]] | ||
}} | }} |
Revision as of 14:09, 19 March 2020
TUFLOW Message
ERROR 2980 - HPC terminated the simulation with an ERROR.
Alternate Message
HPC ERROR Code (see hpc.tlf) = 3010
Message Type
ERROR
Description
HPC TLF error message ERROR 3010: Timestep must be >= 0.015
The minimum timestep has been reached, this changes for your selected cell size.
Suggestions
Inspect downstream boundaries for accidental flow back into the model (turn on vectors). Plot dt .csv file and HPC parameters.
Up |
---|
2xxx Messages |