TUFLOW Message
WARNING 2302 - Green Ampt solution may not have converged.

Alternate Message
NA

Message Type
WARNING

Description
The maximum number of iterations of the Green Ampt solution have been exceeded.

Suggestions
The number of iterations of the Green-Ampt infiltration convergence test have been exceeded. The number of iterations can be changed with the GA Maximum Iterations == command. The GA Convergence Value == command is used to set the convergence tolerance. Refer to the TUFLOW manual for more guidance on these commands.