{{TUFLOW_Message
|tuflow_message=CHECK 3506: Limiting SGS Grid sample frequency to upper limit of 31'a'., sample distance of 'ab'.
<br>
|alt_msg=N/A
 
|type=[[CHECK]]
|message_desc=Too high an SGS sample frequency can result into long pre-processing time, and users may not benefit from applying a super fine sample distance against the model cell size. In general we found a sample frequency smaller than 31 is sufficient for most of the natural channel or artificial structures, and the default frequency limit is set as 31.
|message_desc=The maximum number of sampling points for face is 31.
|suggestions=The default limit can be changed by using a second argument in the <font color="blue"><tt>SGS Grid/TIN Sample Distance</tt></font> command, e.g. <font color="blue"><tt>SGS Grid Sample Distance</tt></font> <font color="red"><tt>== </tt></font> <tt>1</tt> I <tt>50</tt> sets the sampling distance to 1 m and the frequency limit to 51
|suggestions=If more resolution is required, cell size can be lowered.
 
|discussion_page=* [[Talk:TUFLOW Message 3506|Discuss Message 3506]]
|link3=''