Difference between revisions of "TUFLOW Message 2436"

From Tuflow
Jump to navigation Jump to search
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=Hydrographs were not accepted by the HPC solver.
+
|message_desc=Hydrographs were not accepted by the HPC solver. Prior to 2020-01-AC release this error was caused by multiplication factors f1 and f2 in the 2d_rf layer other than 1.
|suggestions=Please contact support@tuflow.com.
+
|suggestions=Use the latest TUFLOW release. If multiplication factors other than 1 are used and TUFLOW version cannot be updated, multiplication should be applied to the source hydrographs rather than the factors f1 and f2.<br>
 +
If the above doesn't apply, please contact support@tuflow.com.
 
|discussion_page=* [[Talk:TUFLOW Message 2436|Discuss Message 2436]]
 
|discussion_page=* [[Talk:TUFLOW Message 2436|Discuss Message 2436]]
 
|link3=''
 
|link3=''

Revision as of 16:41, 18 September 2020

TUFLOW Message
ERROR 2436 - Sending hydrograph weights to HPC Solver.

Alternate Message
NA

Message Type
ERROR

Description
Hydrographs were not accepted by the HPC solver. Prior to 2020-01-AC release this error was caused by multiplication factors f1 and f2 in the 2d_rf layer other than 1.

Suggestions
Use the latest TUFLOW release. If multiplication factors other than 1 are used and TUFLOW version cannot be updated, multiplication should be applied to the source hydrographs rather than the factors f1 and f2.
If the above doesn't apply, please contact support@tuflow.com.


Up
Go-up.png 2xxx Messages