TUFLOW Message 1423: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 10: | Line 10: | ||
|prelink=[[TUFLOW_Message_1422|Message 1422]] |
|prelink=[[TUFLOW_Message_1422|Message 1422]] |
||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
||
|nextlink=[[ |
|nextlink=[[TUFLOW_Message_1425|Message 1425]] |
||
}} |
}} |
||
Revision as of 09:04, 28 May 2021
TUFLOW Message
ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>
Alternate Message
N/A
Message Type
ERROR
Description
Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.
Suggestions
Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.
| Up |
|---|