Difference between revisions of "TUFLOW Message 1092"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
|tuflow_message=ERROR 1092 - No flow area provided for pit type ",a,". | |tuflow_message=ERROR 1092 - No flow area provided for pit type ",a,". | ||
− | |alt_msg=Flow area provided for pit type or yQ curve "a" is less than or equal to zero. | + | |alt_msg=ERROR 1092 - Flow area provided for pit type or yQ curve "a" is less than or equal to zero. |
|type=[[ERROR]]<br> | |type=[[ERROR]]<br> | ||
[[WARNING]] | [[WARNING]] |
Revision as of 08:44, 19 February 2021
TUFLOW Message
ERROR 1092 - No flow area provided for pit type ",a,".
Alternate Message
ERROR 1092 - Flow area provided for pit type or yQ curve "a" is less than or equal to zero.
Description
Caused when a zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If 'Defaults == Pre-2012' is set, a WARNING 1092 or 1093 is issued and the model simulation will not stop.
Suggestions
Check for a null or less than or equal to zero flow area within a Q pit.
Up |
---|
1xxx Messages |