Difference between revisions of "TUFLOW Message 1093"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
|type=[[ERROR]]<br> | |type=[[ERROR]]<br> | ||
[[WARNING]] | [[WARNING]] | ||
− | |message_desc=Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If 'Defaults == Pre-2012' is set, a WARNING 1093 is issued and the model simulation will not stop. | + | |message_desc=Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If '<font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012</tt></font>' is set, a WARNING 1093 is issued and the model simulation will not stop. |
|suggestions=Check for a null or less than or equal to zero width within a Q pit. | |suggestions=Check for a null or less than or equal to zero width within a Q pit. | ||
|discussion_page=* [[Talk:TUFLOW Message 1093|Discuss Message 1093]] | |discussion_page=* [[Talk:TUFLOW Message 1093|Discuss Message 1093]] |
Revision as of 13:42, 23 June 2022
TUFLOW Message
ERROR 1093 - No entry width provided for pit type ",a,".
Alternate Message
ERROR 1093 - Entry width provided for pit type or yQ curve "Wurundjeri W" is less than or equal to zero.
Description
Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If 'Defaults == Pre-2012' is set, a WARNING 1093 is issued and the model simulation will not stop.
Suggestions
Check for a null or less than or equal to zero width within a Q pit.
Up |
---|
1xxx Messages |