===Tool Description===
Checks pipe direction and will correct based on the selected processing option.
Checks pipe direction and will correct based on the selected rule. Based on inverts will check the gradient of the pipe is in the direction of flow. If there is a negative gradient, the tool will switch the pipe direction. Based on pipe direction continuity will do a basic check on places where the pipe direction does not appear to be continuous. It will ignore pipes that connect to junctions with 3 or more other pipes as these can be ambiguous in determining continuity.
 