|message_desc=A TUFLOW 1D (ESTRY) node is trying to be linked to an external 1D scheme, but the TUFLOW node is already linked to a 2D domain via an SX connection. External 1D scheme links should not occur at TUFLOW nodes linked to 2D domains. | |message_desc=A TUFLOW 1D (ESTRY) node is trying to be linked to an external 1D scheme, but the TUFLOW node is already linked to a 2D domain via an SX connection. External 1D scheme links should not occur at TUFLOW nodes linked to 2D domains. | ||
|suggestions=Review connections to external 1D scheme for this node. | |suggestions=Review connections to external 1D scheme for this node. | ||
− | + | ||
− | |||
− | |||
|prelink=[[TUFLOW_Message_1391|Message 1391]] | |prelink=[[TUFLOW_Message_1391|Message 1391]] | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_1393|Message 1393]] | |nextlink=[[TUFLOW_Message_1393|Message 1393]] | ||
}} | }} |
Revision as of 15:46, 5 July 2022
TUFLOW Message
ERROR 1392 - The node is connected to a 2D domain via a SX connection. Cannot connect to an external 1D Scheme.
Alternate Message
NA
Message Type
ERROR
Description
A TUFLOW 1D (ESTRY) node is trying to be linked to an external 1D scheme, but the TUFLOW node is already linked to a 2D domain via an SX connection. External 1D scheme links should not occur at TUFLOW nodes linked to 2D domains.
Suggestions
Review connections to external 1D scheme for this node.