TUFLOW Message 1092: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 4: | Line 4: | ||
|type=[[ERROR]]<br> |
|type=[[ERROR]]<br> |
||
[[WARNING]] |
[[WARNING]] |
||
|message_desc=Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If |
|message_desc=Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If <font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012 </tt></font> is set, a WARNING 1092 is issued and the model simulation will not stop. |
||
|suggestions=Check for a null or less than or equal to zero flow area within a Q pit. |
|suggestions=Check for a null or less than or equal to zero flow area within a Q pit. |
||
Revision as of 09:20, 18 July 2022
TUFLOW Message
ERROR 1092 - No flow area provided for pit type ",a,".
Alternate Message
ERROR 1092 - Flow area provided for pit type or yQ curve "a" is less than or equal to zero.
Description
Caused when a null or less than or equal to zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If Defaults == Pre-2012 is set, a WARNING 1092 is issued and the model simulation will not stop.
Suggestions
Check for a null or less than or equal to zero flow area within a Q pit.