Difference between revisions of "TUFLOW Message 1093"

From Tuflow
Jump to navigation Jump to search
Line 4: Line 4:
 
|type=[[ERROR]]<br>
 
|type=[[ERROR]]<br>
 
[[WARNING]]
 
[[WARNING]]
|message_desc=Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If '<font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012</tt></font>' is set, a WARNING 1093 is issued and the model simulation will not stop.
+
|message_desc=Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If <font color="blue"><tt>Defaults </tt></font><font color="red"><tt>== </tt></font><font color="black"><tt>Pre-2012</tt></font> is set, a WARNING 1093 is issued and the model simulation will not stop.
 
|suggestions=Check for a null or less than or equal to zero width within a Q pit.
 
|suggestions=Check for a null or less than or equal to zero width within a Q pit.
  

Revision as of 09:21, 18 July 2022

TUFLOW Message
ERROR 1093 - No entry width provided for pit type ",a,".

Alternate Message
ERROR 1093 - Entry width provided for pit type or yQ curve "Wurundjeri W" is less than or equal to zero.

Message Type
ERROR
WARNING

Description
Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If Defaults == Pre-2012 is set, a WARNING 1093 is issued and the model simulation will not stop.

Suggestions
Check for a null or less than or equal to zero width within a Q pit.


Up
Go-up.png 1xxx Messages