Difference between revisions of "TUFLOW Message 3036"

From Tuflow
Jump to navigation Jump to search
Line 9: Line 9:
 
If the above doesn't apply, please contact <u>[mailto:support@tuflow.com support@tuflow.com]</u>.
 
If the above doesn't apply, please contact <u>[mailto:support@tuflow.com support@tuflow.com]</u>.
  
|discussion_page=* [[Talk:TUFLOW Message 3036|Discuss Message 3036]]
 
|link3=''
 
|link4=''
 
 
|prelink=[[TUFLOW_Message_3035|Message 3035]]
 
|prelink=[[TUFLOW_Message_3035|Message 3035]]
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
 
|uplink=[[3xxx_TUFLOW_Messages|3xxx Messages]]
 
|nextlink=[[TUFLOW_Message_3037|Message 3037]]
 
|nextlink=[[TUFLOW_Message_3037|Message 3037]]
 
}}
 
}}

Revision as of 15:21, 13 July 2022

TUFLOW Message
ERROR 3036: Hydrograph weight data not in range [0 ... 6.5535].

Alternate Message
None

Message Type
ERROR

Description
Hydrographs were not accepted by the HPC solver. Prior to 2020-10-AA release this error was caused by multiplication factors f1 and f2 in the 2d_rf layer other than 1.

Suggestions
Use the latest TUFLOW release. If multiplication factors other than 1 are used and TUFLOW version cannot be updated, multiplication should be applied to the source hydrographs rather than the factors f1 and f2.
If the above doesn't apply, please contact support@tuflow.com.


Up
Go-up.png 3xxx Messages