Difference between revisions of "TUFLOW Message 1214"
Jump to navigation
Jump to search
Line 6: | Line 6: | ||
|suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank. | |suggestions=If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank. | ||
− | + | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
− | |||
}} | }} |
Latest revision as of 15:52, 22 December 2022
TUFLOW Message
ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.
Alternate Message
WARNING 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.
Description
From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
Suggestions
If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
Up |
---|
1xxx Messages |