Difference between revisions of "TUFLOW Message 1314"

From Tuflow
Jump to navigation Jump to search
 
Line 6: Line 6:
 
|suggestions=Check manhole and culvert dimensions and correct.
 
|suggestions=Check manhole and culvert dimensions and correct.
  
|prelink=[[TUFLOW_Message_1313|Message 1313]]
 
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
 
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|nextlink=[[TUFLOW_Message_1315|Message 1315]]
 
 
}}
 
}}

Latest revision as of 10:28, 23 December 2022

TUFLOW Message
ERROR 1314 - Maximum flow width of one or more culverts exceeds manhole flow width.

Alternate Message
NA

Message Type
ERROR

Description
The flow width of the manhole is less than the width of a culvert connected. For example a 1.8m wide culvert is connected to a manhole with a width of 1.5m. Data doesn't agree.

Suggestions
Check manhole and culvert dimensions and correct.